StdDev LiDo

Author: Copyright © 2021, Vladimir Karputov
Indicators Used
Standard Deviation indicator
1 Views
0 Downloads
0 Favorites
StdDev LiDo
ÿþ//+------------------------------------------------------------------+

//|                                                  StdDev LiDo.mq5 |

//|                              Copyright © 2021, Vladimir Karputov |

//|                     https://www.mql5.com/ru/market/product/43516 |

//+------------------------------------------------------------------+

#property copyright "Copyright © 2021, Vladimir Karputov"

#property link      "https://www.mql5.com/ru/market/product/43516"

#property version   "1.000"

#property indicator_separate_window

#property indicator_buffers 2

#property indicator_plots   2

//--- plot RSI

#property indicator_label1  "StdDev"

#property indicator_type1   DRAW_LINE

#property indicator_color1  clrDodgerBlue

#property indicator_style1  STYLE_SOLID

#property indicator_width1  1

//--- plot RSI_Dot

#property indicator_label2  "StdDev Dot"

#property indicator_type2   DRAW_ARROW

#property indicator_color2  clrLime

#property indicator_style2  STYLE_SOLID

#property indicator_width2  1

//--- input parameters

input group             "StdDev"

input int                  Inp_StdDev_ma_period    = 10;          // period of averaging

input int                  Inp_StdDev_ma_shift     = 0;           // shift

input ENUM_MA_METHOD       Inp_StdDev_ma_method    = MODE_SMA;    // type of smoothing

input ENUM_APPLIED_PRICE   Inp_StdDev_applied_price= PRICE_CLOSE; // type of price

input group             "Arrow"

input uchar                InpArrowCode            = 159;         // Arrow code "SELL"

//--- indicator buffer

double   StdDevBuffer[];

double   StdDevDotBuffer[];

//---

int      handle_iStdDev;                  // variable for storing the handle of the StdDev indicator

int      bars_calculated=0;               // we will keep the number of values in the StdDev

//+------------------------------------------------------------------+

//| Custom indicator initialization function                         |

//+------------------------------------------------------------------+

int OnInit()

  {

//--- indicator buffers mapping

   SetIndexBuffer(0,StdDevBuffer,INDICATOR_DATA);

   SetIndexBuffer(1,StdDevDotBuffer,INDICATOR_DATA);

//--- setting a code from the Wingdings charset as the property of PLOT_ARROW

   PlotIndexSetInteger(1,PLOT_ARROW,InpArrowCode);

//--- sets first bar from what index will be drawn

   PlotIndexSetInteger(0,PLOT_DRAW_BEGIN,Inp_StdDev_ma_period);

//--- name for DataWindow and indicator subwindow label

   IndicatorSetString(INDICATOR_SHORTNAME,"StdDev("+IntegerToString(Inp_StdDev_ma_period)+")");

//--- create handle of the indicator iStdDev

   handle_iStdDev=iStdDev(Symbol(),Period(),Inp_StdDev_ma_period,Inp_StdDev_ma_shift,Inp_StdDev_ma_method,Inp_StdDev_applied_price);

//--- if the handle is not created

   if(handle_iStdDev==INVALID_HANDLE)

     {

      //--- tell about the failure and output the error code

      PrintFormat("Failed to create handle of the iStdDev indicator for the symbol %s/%s, error code %d",

                  Symbol(),

                  EnumToString(Period()),

                  GetLastError());

      //--- the indicator is stopped early

      return(INIT_FAILED);

     }

//---

   return(INIT_SUCCEEDED);

  }

//+------------------------------------------------------------------+

//| Custom indicator iteration function                              |

//+------------------------------------------------------------------+

int OnCalculate(const int rates_total,

                const int prev_calculated,

                const datetime &time[],

                const double &open[],

                const double &high[],

                const double &low[],

                const double &close[],

                const long &tick_volume[],

                const long &volume[],

                const int &spread[])

  {

//---

   int values_to_copy;

//--- determine the number of values calculated in the indicator

   int calculated=BarsCalculated(handle_iStdDev);

   if(calculated<=0)

     {

      PrintFormat("BarsCalculated() returned %d, error code %d",calculated,GetLastError());

      return(0);

     }

//--- if it is the first start of calculation of the indicator or if the number of values in the iStdDev indicator changed

//---or if it is necessary to calculated the indicator for two or more bars (it means something has changed in the price history)

   if(prev_calculated==0 || calculated!=bars_calculated || rates_total>prev_calculated+1)

     {

      //--- if the iRSIBuffer array is greater than the number of values in the iStdDev indicator for symbol/period, then we don't copy everything

      //--- otherwise, we copy less than the size of indicator buffers

      if(calculated>rates_total)

         values_to_copy=rates_total;

      else

         values_to_copy=calculated;

     }

   else

     {

      //--- it means that it's not the first time of the indicator calculation, and since the last call of OnCalculate()

      //--- for calculation not more than one bar is added

      values_to_copy=(rates_total-prev_calculated)+1;

     }

//--- fill the array with values of the Standard Deviation indicator

//--- if FillArrayFromBuffer returns false, it means the information is nor ready yet, quit operation

   if(!FillArrayFromBuffer(StdDevBuffer,Inp_StdDev_ma_shift,handle_iStdDev,values_to_copy))

      return(0);

   if(!FillArrayFromBuffer(StdDevDotBuffer,Inp_StdDev_ma_shift,handle_iStdDev,values_to_copy))

      return(0);

//--- memorize the number of values in the StdDev

   bars_calculated=calculated;

//--- return value of prev_calculated for next call

   return(rates_total);

  }

//+------------------------------------------------------------------+

//| Filling indicator buffers from the iStdDev indicator             |

//+------------------------------------------------------------------+

bool FillArrayFromBuffer(double &std_buffer[],  // indicator buffer of the Standard Deviation line

                         int std_shift,         // shift of the Standard Deviation line

                         int ind_handle,        // handle of the iStdDev indicator

                         int amount             // number of copied values

                        )

  {

//--- reset error code

   ResetLastError();

//--- fill a part of the iStdDevBuffer array with values from the indicator buffer that has 0 index

   if(CopyBuffer(ind_handle,0,-std_shift,amount,std_buffer)<0)

     {

      //--- if the copying fails, tell the error code

      PrintFormat("Failed to copy data from the iStdDev indicator, error code %d",GetLastError());

      //--- quit with zero result - it means that the indicator is considered as not calculated

      return(false);

     }

//--- everything is fine

   return(true);

  }

//+------------------------------------------------------------------+

//| Indicator deinitialization function                              |

//+------------------------------------------------------------------+

void OnDeinit(const int reason)

  {

   if(handle_iStdDev!=INVALID_HANDLE)

      IndicatorRelease(handle_iStdDev);

  }

//+------------------------------------------------------------------+

Comments

Markdown supported. Formatting help

Markdown Formatting Guide

Element Markdown Syntax
Heading # H1
## H2
### H3
Bold **bold text**
Italic *italicized text*
Link [title](https://www.example.com)
Image ![alt text](image.jpg)
Code `code`
Code Block ```
code block
```
Quote > blockquote
Unordered List - Item 1
- Item 2
Ordered List 1. First item
2. Second item
Horizontal Rule ---